Passeclair | Mavifood | Maviroll | Mavifold | Mavicold | Maviswing |
|
MAVICOLD High-Speed Fold-Up Door |
|
|
Frame Characteristics Self supporting mill galvanized steel frame with polyester powder coated finish for maximum anti-corrosion protection. Thermal break frame construction eliminates frost. Standard colour Grey RAL 7016, other RAL colours available on request. Strip heaters mounted on the frame minimize frost and ice build-up. Options:
Frame
in stainless steel AISI 304 Lor 316L ensures food safe
applications. |
|
Mavicold
Unique Design Uprights and transform fully boxed with double insulated fabric (same colour as curtain). Silicon heating tapes on uprights. Two piece uprights for ease of replacement in the event of damage. Semi rigid curtain side guides in water repellent material elimates frots and give operate with silent. Insulated Curtain Energy efficient curtain
construction: heat and humidity are reflected away and
separated from cold by innovative fabric with high
thermal efficiency: K=2W/m²/°C. |
|
Active
insulation technology Multi-reflective thermal insulation = heat from outside is deflected back out-side = cold generated within the cold room is reflected back inside. Thin curtain with high insulation. Reduced sound transmission and resonance. Greater durability in high impact area. Curtain built in draft resistance (ensure complete closure) is equipped with peripheric seals and fibreglass - (GRP) - horizontal strengtheners. Curtain folding method minimizes frost and ice build up. The Hangar Mavicold
door is equipped with seamless safety straps (3900 daN
per strap) for added safety. |
|
Multi Safety Devices Complies with NF P 25-362 safety standard. Soft bottom edge technology. "Safety Strap System". Dual safety stainless steel photocells mounted within the doorway reverses the curtain in event of obstruction. 2 orange warning lights (each side of the door) flash when the door operates. Fail safe circuits. Operating and Maintenance instructions. Peripheral Seals Airtight seals between the curtain, frame and top hood. Airtight seals between
the frame and opening structure. |
|
Clear Dimensions Maximum clear opening 4000 x 4000 mm Overall width = Clear + 440 mm Overall height = Clear +
780 mm |
|
Draft/Pressure Resistance Designed to withstand pressure differential across curtain equivalent to 80 km/h wind speed. High-Speed Operation Opening & closing: Maximum speed -1m/s. Opening Devices Push button ceiling pull
switch, induction floor loop, radio control, other
controls on request. |
|
Technical Gear Motor: Heated gear brake motor unit to IP 55. Conical torque. Brake disc and brake shield in stainless steel. One speed 0.55 kW motor: permanent service rating S1. Gear unit with low-temp oil (-30°C). Drum: Protected by anti corrosion coated finish. Control Box: CE marked and IP 55 to be located outside the cold room. Main components are Telemecanique 50-60Hz. Option: Heater in the control box when mounted inside the freezer. Fibreglass or stainless steel control box IP 66(NEMA 4 X enclosure). |
|
Electrical Installation Strip heaters are protected by 30mA differential cut-out. Voltage: 240V or 400 V, 3 phase with earth and neutral. Circuit breaker or cut-out switch on line D type curve. Installation Cold Side Mount Frame and curtain lifting straps to be facing the cold area. |
|
10 Frame and Curtain Colours Available
White | Orange | Red | Ivory | Yellow |
RAL 9016 | RAL 2004 | RAL 3002 | RAL 1015 | RAL 1021 |
Green | Blue | Blue | 358 Light Grey | Green |
RAL 6026 | RAL 5015 | RAL 5002 | RAL 7016 | RAL 6018 |